Ventis Medical HeroVent Emergency and Transport Ventilator
by North American Rescue
Ventis Medical HeroVent Emergency and Transport Ventilator is a compact, turbine driven ventilator engineered for rapid deployment by EMS, air medical crews, tactical medics, and hospital teams. The unit features automatic preset configurations for common emergencies, a 5 in. touchscreen with full color interactive video guidance, and modes including A C assist control, SIMV, CPAP, NIV and pressure support. It delivers precise tidal volumes from 200 to 2000 mL, adjustable FiO2 from 14 to 100 percent, EtCO2 waveform monitoring, and inspiratory times from 0.3 to 5.0 seconds. Lightweight at approximately 3 lbs with support for rechargeable and disposable batteries, the HeroVent meets military grade standards for durability and is easy to maintain. Ideal for transport and prolonged care, it combines advanced monitoring with simple operation to improve patient outcomes. Shop MyAED for fast shipping and expert support.
Ventis Medical HeroVent Emergency and Transport Ventilator
Rapid Response Ventilation for First Responders
The HeroVent is built for emergency teams who need reliable ventilatory support on scene and in transit. Settings are automatically configured for common emergency scenarios, allowing paramedics, flight crews, and tactical medics to initiate effective ventilation fast. With assist control, SIMV, CPAP, NIV and pressure support modes available, the HeroVent adapts to apneic patients and those requiring spontaneous breathing support. Lightweight at about 3 lbs with on board battery power, it reduces carry weight while delivering volumes from 200 to 2000 mL and a respiratory rate range to 40 BPM. The device solves the problem of complex setup in time critical care, by providing preset modes, clear prompts, and dependable performance under stress.
Turbine Driven Design with Smart Interface
At the heart of the HeroVent is turbine technology that produces consistent flow without requiring compressed gas, making it ideal for transport and austere environments. The 5 in. touchscreen presents a full color interactive display with step by step video guidance for circuit connection and testing, reducing training time and setup errors. FiO2 is adjustable from 14 to 100 percent, EtCO2 waveforms are available for monitoring, and inspiratory time can be set from 0.3 to 5.0 seconds. Trigger sensitivity and accurate control of tidal volume and peak inspiratory pressure ensure precise support for adults and large children, while compatibility with non proprietary accessories keeps logistics simple.
Built Tough, Maintained Easily
Engineered to military grade standards, the HeroVent balances rugged durability with service friendly design. The compact housing protects internal components during transport, while modular interfaces and accessible panels make routine maintenance straightforward for fleet managers. Peak inspiratory pressure ranges up to 90 cmH2O and PEEP settings cover clinical needs to 20 cmH2O, providing robust performance in critical cases. The unit accepts both rechargeable and disposable batteries for mission flexibility, and it is lightweight without sacrificing construction quality. Built for frequent movement, it stands up to vibration, bumps, and rapid deployment, while software guided checks keep the ventilator ready for immediate use.
Adaptable Platform for Multiple Care Settings
HeroVent serves across a wide range of clinical settings, from ground ambulances and air transport, to forward surgical teams and prolonged field care. Custom preset modes let clinicians save and recall therapy profiles for specific mission types or patient populations, while continuous monitoring of FiO2 and EtCO2 supports evolving patient needs. The device supports invasive ventilation and non invasive ventilation, and it functions reliably during prolonged transfers or interfacility flights. Its small footprint and turbine independence from external gas make it suitable for static emergency departments, tactical medic kits, and mobile care tents, offering a single ventilator solution for varied operational demands.
Applications
Professional Use
- Military field medicine and forward surgical teams
- Air medical transport and helicopter EMS
- Ground ambulance and critical care transport
- Tactical medicine units and law enforcement medics
- Hospital emergency departments and ICU surge support
Training and Civilian Use
- EMS training programs and simulation labs
- Prolonged care courses and wilderness medicine
- Industrial rescue teams and remote worksites
- First aid stations at mass events and sports venues
- Preparedness kits for hospitals and community responders
Product Specifications
Alarms
- Tidal Volume: 0 to 2000 Ml
- FiO2: 14 - 100%
- Respiratory Rate (RR): 1 to 40 BPM
- EtCO2: 0 to 10 Kpa
- Peak Inspiratory Pressure (PIP): 0 to 90 CmH2O
- Positive End Expiratory Pressure (PEEP): > 5 CmH2O
- Apnea: 10 - 60s
Controls
- Tidal Volume: 200 to 2000 Ml
- Trigger Sensitivity(Flow): OFF, 1 - 9 LPM
- Respiratory Rate (RR): 0 to 40 BPM
- Inspiratory Time: 0.3 to 5.0 Seconds
- Peak Inspiratory Pressure (PIP): 15 to 90 CmH2O
- Positive End Expiratory Pressure (PEEP): 0 to 20 CmH2O
Measured and Displayed Patient Parameters
- Tidal Volume: 0 to 2000 Ml
- FiO2: 14 - 100%
- Respiratory Rate (RR): 0 to 100 BPM
- EtCO2 with CO2 Accessory: 0 to 10 Kpa
- Peak Inspiratory Pressure (PIP): 0 to 90 CmH2O
Ventilation Modes
- A/C: Assist Control (Volume Control
- CPAP: Continuous Positive Airway Pressure
- SIMV: Synchronized Intermittent Ventilation (Volume Control)
- NIV: Non-Invasive Ventilation
- PS: Pressure Support
Environmental
- 201.15.3.5.101.1 Shock and Vibration (Robustness)
- 201.15.3.5.101.2 Shock and Vibration for a Transit-Operable Ventilator During Operation
Physical Specifications
- Dimensions: 8 in. x 6.5 in. x 2.25 in.
- Weight: ~ 3 lbs. with battery
- Screen Size: 5 in. diagonal
- Ingress Protection: IP 54
- Atmospheric Pressure: 620 - 1060 hPa
- Operating Temperature: -10°C/14°F to 40°C/104°F
- Storage Temperature: -40°C/F to 70°C/158°F
- Operating Time:
- Disposable Battery: 6 hours
- Rechargeable Battery: 8 hours
- Charging Time:
- Off: 3 hours
- Ventilating: 5 hours
Standards
- IEC 60601 - 1:2005/AMD2:2020
- IEC 60601 - 1:2005/AMD2:2020 Including IEC 62366-1 (2025) + A 1 (2020)
- IEC 60601-1-1-8 (2026) +A2(2020)
- IEC 60601-1-1-8 (2014) +A2(2020)
- ISO 80601 - 2 -12(2023)
- ISO 80601 - 2 - 55(2023)
- ISO 80601 - 2 - 84(2023)
- AAMI Standards: TIR38:2017
- ISO 80601-2-12:2021 including
- ISO 5356-1:2015
- ISO 5367:2014
- ISO 80601-2-55:2018 ISO 80601-2-84:2020
- ANSI/AAMI ES 60601 - 1:2005 + A 1:2012 + A2: 2021
- CAN/CSA C22.2 No. 60601 - 1:2008 + A1:2014 + A 2:2022